<Error>
<ErrorNumber>16072</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: Plate rejected because it was cancelled too late in the imaging sequence
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
For integrating media such as the T96-3 plate, special care must be taken to avoid image
artifacts.  Stray light from the light valve will expose the plate in a very short amount
of time.  If the job is cancelled any time after the focus learn starts, the plate is considered a
reject.  This is because a second focus learn will cause a dark line to appear on the plate.
</text></DescriptionText>
<DescriptionText><text>
The parameter "media slf" will have been set to 1 to indicate this integrating feature of the
plate.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This message should only ever appear as a warning message.  It means that the plate cannot
be re-used and will be unloaded.  This will only happen after a job has been cancelled, not in
normal operation.
</text></DescriptionText>
</OperatorAction>
<Cause>
Job cancelled after focus learn, and media is integrating so plate cannot be re-used.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/media_cal_slf.xml</LinkAddress><LinkTitle>NVS: media slf</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:32 2008 PST
</Updated>
<Links>
</Links>
</Error>